| wdt_ID | wdt_created_by | wdt_created_at | wdt_last_edited_by | wdt_last_edited_at | Product |
|---|---|---|---|---|---|
| 1 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Product model |
| 2 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Standard configuration |
| 3 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Light curtain source |
| 4 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Application |
| 5 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Features |
| 6 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Number of beams |
| 7 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Resolution |
| 8 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Protect Height |
| 9 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Overall Height |
| 10 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Cross-section size |
| 11 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Response time |
| 12 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Synchronization |
| 13 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Output mode |
| 14 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Output status |
| 15 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Indicator light |
| 16 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Wavelength |
| 17 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Type of light |
| 18 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Function |
| 19 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Mechanical data |
| 20 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Housing material |
| 21 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Metal shell |
| 22 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Lens front screen material |
| 23 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Upper and lower cover materials |
| 24 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Performance data |
| 25 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Protection circuit |
| 26 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Supply voltage |
| 27 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Output Current |
| 28 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Fuse |
| 29 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Maximum residual current |
| 30 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Environmental data |
| 31 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Protection grade |
| 32 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Anti-optical interference |
| 33 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Operating Temperatuer |
| 34 | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | afetycurtainadministrator-Michelle | 11/05/2026 09:40 AM | Operating Humidity |
4-Beam Industrial Safety Light Curtain Sensor with IP65
Designed for industrial environments, this infrared safety light curtain includes transmitter and receiver, 4 beams, 40mm resolution, 120mm protection height, ≤15ms response, DC24V power, metal housing, acrylic lens, IP65 rating, and automatic reset.
|
Wiring Diagram
Use the wiring diagram below to connect the safety light curtain emitter and receiver correctly. The sensor supports different output types, including NPN/NC and PNP/NC, depending on the selected model.
Wire Connection
| Wire Color | Function | Description |
|---|---|---|
| Brown | VCC | DC24V power supply |
| Blue | GND | 0V power ground |
| Black | OSSD1 | Safety output 1 |
| Grey | OSSD2 | Safety output 2 |
| Yellow | PE | Protective earth connection |
| White | CP | Communication / synchronization line |
NPN Output Wiring
For NPN models, connect OSSD1 Black and OSSD2 Grey according to the NPN/NC wiring diagram. Ensure the load and control circuit are compatible with NPN output signals.
PNP Output Wiring
For PNP models, connect OSSD1 Black and OSSD2 Grey according to the PNP/NC wiring diagram. Ensure the load and control circuit are compatible with PNP output signals.
Installation Notes
Before wiring, disconnect the power supply and confirm the output type of the safety light curtain. Use a stable DC24V power supply and follow the wiring diagram carefully to ensure safe and reliable operation. Wiring should be completed by qualified personnel.